The Oscillome›Programs›C

Program C · 4 sections

Spatial dynamics

How alpha's phase and amplitude are organized across the scalp, and how much of that fourteen sensors can resolve.

Supported associationAlpha's back-to-front lag asymmetry survives eye closure under LSD and not otherwise: +0.25 to +0.35 in six of six sessions against a median of +0.01.

  1. §12Alpha's phase gradient: mostly the eyes, a little beyond them
  2. §13Watching a wave cross the scalp
  3. §14A right-leaning brain — and how much of it is the headset
  4. §15An office state with restricted dynamics

12 — Phase gradients Retrospective · exploratory

Alpha's phase gradient: mostly the eyes, a little beyond them

Analysis basis 56-recording cohort (19 vs 37) · dataset release 2026.10.10 · last recomputed in analysis release 4.26 · current

Fourteen electrodes give more than fourteen spectra: they give the spatial phase of the oscillation. Fit a plane to it and alpha acquires a phase-gradient vector — a direction and a steepness across the scalp. In psychedelic-labeled sessions that gradient is nearly twice as steep and much better fitted than in ordinary recordings, and earlier versions of this section read that as alpha traveling. The eye-state labels of v4 show what most of it is: the gradient steepens almost four-fold whenever the eyes close, in every recording that has both states, psychedelic or not. What remains once eye state is matched is a modest difference in the same direction.

What the measure responds to

60-second windows, whole archiveWindowsGradient |k|Plane-fit R²
Eyes open2,7140.310.16
Mixed3050.890.38
Eyes closed6741.180.48

Within a recording, closed exceeds open in 16 of 16 recordings that contain at least five windows of each (median difference +0.89, p = 0.00003), ordinary recordings included: Workday recording 013 goes from 0.41 to 1.65. The group contrast this section was built on — psychedelic 0.71 against ordinary 0.42, a ratio of 1.70 (p = 0.001), over all windows — falls to a ratio of 1.31 (0.45 against 0.34, p = 0.057) when only eyes-open windows are used, and reverses among eyes-closed windows (1.26 against 1.49; twelve recordings against five). The eye-state labels here are the classifier's, and the classifier reads alpha, so this matching also matches partly on alpha strength, on which a phase gradient depends; the timed blocks of protocol P2 are the cleaner test (Methods).

Simulation says why. Given a pure traveling wave and an ideal reference, the estimator recovers the true wavenumber exactly. With this headset's reference near P3/P4 and a standing alpha three times the traveling one — which is what real alpha looks like — it returns 0.4–0.6 whatever the truth (rank correlation with the truth 0.12). Two standing sources with a phase lag and no traveling wave at all reproduce the whole published range, 0.1 to 1.2, with plane fits of R² above 0.9. And at a fixed lag the estimate rises with alpha's signal-to-noise ratio, from 0.17 to 0.74 over 16 dB, falling to 0.02 for pure noise. Eye closure multiplies alpha two- to eight-fold (§16). On fourteen sensors this is a measure of how strongly a lagged front–back alpha pattern stands out of the noise; it is not a wavelength.

How the wave vector is measured

For each clean 60-second window the alpha-band analytic signal is computed on all channels. Every electrode pair gives a mean cross-phase and a phase-locking weight. A weighted least-squares fit of φi − φj ≈ kx(xi−xj) + ky(yi−yj) over the 2-D electrode positions returns the wave vector k, its magnitude in radians per head-radius, its direction, and the fit's circular R². A standing-mode score is built separately from the dominance and stability of the leading spatial-covariance mode and its 0/π phase locking.

This is a scalp-level phase gradient, not source localization, and the absolute direction convention is not validated against a known traveling stimulus. Contrasts between states are the trustworthy quantity; the compass labels are provisional.

What changes

Psychedelic ÷ non-psychedelic median for eight wave measures, 19 vs 37 recordings, recording-level permutation p-values.
Phase-gradient magnitude
1.70×

|k| 0.42 → 0.71 rad per head-radius, p < 0.001. Steeper phase gradient: greater phase rotation across the montage. With fourteen electrodes this does not fix a wavelength or show propagation (see the identifiability panel above).

Plane-wave fit
R² 0.19 → 0.31

p = 0.002. The phase field is better fit by a planar phase pattern.

Plane-wave (“traveling”) score
3.9×

1.9 → 7.3, p < 0.001. Standing score also rises (5.5 → 11.0, p < 0.001): more organization of both kinds.

Global synchrony
unchanged

Kuramoto order 0.54 vs 0.52, p = 0.08. Whatever steepens the gradient, it is not more synchrony overall.

Which way the gradient points

Each arrow is one recording's mean phase-gradient direction; length is its consistency across windows (resultant length 0–1). Bold arrow: the group mean. Data (CSV)

Non-psychedelic recordings point every which way and weakly. Psychedelic recordings agree: fourteen of nineteen have a posterior-pointing mean gradient, and the median fraction of windows pointing anterior falls from 70% to 44% (p < 0.001). The three sessions added in October (two ayahuasca, one psilocybin) are among the five that point the other way, so the direction agreement is weaker than the sixteen-session version suggested. A note on sign: the phase used here is the Hilbert phase, which advances with time, so a phase gradient points opposite to the direction of travel, and a posterior-pointing gradient corresponds to travel toward the front, the direction whose packets §13 counts. This estimator's sign convention has not been checked against a wave of known direction (see the end of this section), and LSD, the class with the clearest front-going packets in §13, has the lowest posterior-pointing share here (47%). The most consistent gradient with twenty or more windows is Ayahuasca experiment 006 (246 windows, resultant length 0.83, |k| = 1.02), with two DMT sessions and the other ayahuasca night at 0.76–0.78. One eyes-open desk recording, Workday recording 014, has the highest resultant length in the archive (0.89) with a small, poorly fitted gradient: consistency alone is not the signature.

Most of the difference between psychedelic-labeled and ordinary sessions on this measure is the difference between closed and open eyes.

It is alpha's wave, not the scalp's

A conducted artifact — reference geometry, skull blurring, a shared source seen from fourteen angles — would put the same phase gradient on every frequency band. It does not. Fitting the same plane wave to theta and beta gives a different answer:

Band|k| non-psychedelic|k| psychedelicFit R² non-psy.Fit R² psy.Plane-wave score non-psy.Plane-wave score psy.
Theta 4–8 Hz0.360.340.210.171.61.4
Alpha 8–13 Hz0.340.620.150.231.23.7
Beta 13–30 Hz0.090.260.170.160.60.9

Theta does nothing — if anything it is slightly less organized under psychedelics. Beta's |k| rises but its fit does not, and beta at 21 Hz under LSD is largely the alpha harmonic of §11 riding along. The gradient is a property of the alpha band specifically — which rules out a purely conducted artifact, and is also exactly what eye closure predicts, since closing the eyes raises alpha and leaves theta and beta nearly alone.

Every window in the archive

Color Show
The alpha wave vector of every clean 60-second window in the archive, up to 120 per recording (4,625 in all), plotted as (kx, ky) with the nose up. Non-psychedelic windows crowd the origin; psychedelic windows spread outward and downward. Hover for the recording; click to open.

The whole archive, minute by minute

|k| across each session, time normalized to the session length, one strip per recording, psychedelic sessions first. Brighter is a steeper phase gradient. Click a strip to open that recording's full wave analysis. Data (CSV)
Early, middle and late thirds of each session: recording-level medians of |k|, fit R², plane-wave (“traveling”) and standing scores, then the median across recordings.

How it evolves within a session

Non-psychedelic sessions are flat: |k| 0.37 → 0.36 → 0.34, fit and scores unchanged. Psychedelic sessions are not. |k| rises after the first third and stays up (0.55 → 0.67 → 0.66) and the standing score climbs steadily (8.0 → 10.5 → 12.1), so the field becomes more organized as the session proceeds. That matches the alpha trajectory of §08 — suppressed early, rebuilt late — and says the late-session alpha is not a return to baseline but a more structured alpha than the one the session started with.

By psychedelic class

ClassSessions|k|Fit R²Plane-wave scoreStandingDirection consistencyWindows pointing posteriorPairwise phase locking
Ayahuasca40.840.429.011.60.7657%0.51
DMT70.790.367.612.20.5864%0.49
LSD60.670.256.29.60.4647%0.48
Psilocybin20.770.246.29.60.3035%0.45
None370.420.191.95.50.4730%0.35

Ayahuasca no longer tops every wave measure. Revised. With two sessions it led on magnitude, fit, direction consistency and phase locking; with four it leads only on direction consistency (0.76) and the standing score, and sits below DMT and LSD on |k| (0.84 against 0.79 and 0.67). The two October nights were less eyes-closed than the first two (37% and 22% against 46% and 67% by the v4 classifier), which is the direction §12 predicts for every one of these measures, so the September ordering was partly the eye state of two nights. The second psilocybin session, 61% eyes-closed, does not look like an ordinary recording on these measures, where the first, 4% eyes-closed, did; the class median now sits between LSD and DMT on |k| and fit.

What the numbers would mean physically

Illustrative conversion to a wavelength and a speed (legacy interpretation, not a measured cortical wavelength)

Read literally — which the panel at the top of this section argues it should not be — |k| is a phase-gradient magnitude in radians per head-radius, and converting it to a spatial frequency gives the following. Taking a head radius of about 9 cm, the psychedelic alpha median of 0.62 is a spatial frequency of roughly 6.9 rad/m: a wavelength near 0.9 m, and, at 10 Hz, an apparent phase speed of about 9 m/s. The non-psychedelic median of 0.34 gives a wavelength of 1.7 m and a speed near 17 m/s — long and fast enough that the whole scalp is effectively in phase, which is what a standing pattern is. Across the front-to-back span of the montage, that is a phase difference of about 60° under psychedelics (70° for ayahuasca) against 33° without. Speeds of a few meters per second are what the traveling-wave literature12 reports for macroscopic cortical waves carried by long-range white-matter connections, and they are far too fast for local horizontal fibers. So the wave, if it is a wave, is a cortico-cortical one.

Two caveats hold these numbers loosely. The head radius is assumed, not measured, and the scalp blurs cortical phase, so the true cortical gradient is steeper than the scalp one. And the direction sign convention has not been validated against a driven stimulus. The photic-driving experiment of §18 addresses both: a flicker of known frequency produces a wave of known origin, and its measured direction calibrates the compass.

Every recording page carries its own wave-vector analysis — the minute-by-minute |k| and fit, the phase-gradient portrait, the leading spatial mode, the standing-versus-traveling trace for all six bands, and the original standing-mode dashboard.

If part of the gradient does reflect propagation, the mechanistic reading connects to §06. A standing alpha pattern is what thalamocortical loop models produce when cortex is driven roughly in phase everywhere. A phase gradient with a stable direction is consistent with a phase lag that accumulates across cortex (on fourteen sensors, lagged sources that do not propagate can produce the same pattern), which in the traveling-wave literature (Muller et al. 2018; Zhang et al. 2018)12,13 is associated with cortico-cortical rather than purely thalamic drive. On this montage that remains a hypothesis: the measurement is a directional phase structure, compatible with propagating-wave dynamics and equally with a lagged standing pattern, and §13 is where the distinction is pushed as far as fourteen sensors allow.

What the eyes-closed photic sessions showed

The September photic sessions first showed what the v4 labels then measured: two non-psychedelic eyes-closed photic sessions exceeded the psychedelic medians on every wave measure, while the eyes-open desk session recorded the same week looked like the old office group. The calibration the sign convention needs — a wave-vector analysis of the driven windows, whose source is known — is still owed, and the head radius is still assumed. §18.

13 — Waves in motion Retrospective · exploratory

Watching a wave cross the scalp

Analysis basis 36 ordinary recordings pooled for the eyes-open and eyes-closed direction indices and 9 psychedelic sessions with an eye-state split (6 LSD, 1 psilocybin, 2 ayahuasca); 9 recordings for the September interaction tests, with the 15 October recordings run through the same chain · dataset release 2026.10.10 · last recomputed in analysis release 4.26 · current

§12 measured alpha's phase gradient one minute at a time. This section slows the recording down twenty-fold and shows single waves as they happen: the field painted across the scalp, the fourteen traces beneath it, and the same moment on the cortex. Every clip is real data from this archive. The color between electrodes is interpolated; the electrodes are not. Then it asks three things of the whole archive: where a direction of travel survives its controls, whether any band other than alpha has one, and what two waves do when they share the head.

The claim, in five lines

Observation
Among alpha packets of two or more cycles, anterior-going exceed posterior-going by +0.25 to +0.35 with eyes closed in six of six LSD sessions, by +0.34 after the psilocybin dose and by +0.27 and +0.31 in the two ayahuasca sessions, against +0.01 pooled over the ordinary eyes-closed recordings.
Status
9 psychedelic sessions (6 LSD, 1 psilocybin, 2 ayahuasca) vs 36 ordinary recordings; within one LSD session +0.02 before the dose, +0.41 after, and within the psilocybin session −0.02 before, +0.34 after; lag-free null within ±0.03. Retrospective, eye state matched.
Interpretation
Eyes-closed visual cortex under LSD behaves as it does with visual input, as reported for DMT.
Alternatives
Eye state outside the timed blocks is a classifier estimate built from posterior alpha, so matching on it also partly matches on alpha strength; a lag asymmetry between standing sources rather than propagation; much ordinary eyes-closed time was recorded during flicker; the other three classes are not yet split by eye state.
Discriminating test
The same split for the ten DMT, ayahuasca and psilocybin sessions; imagery ratings per block under protocol P4.
Clip Speed
Time
Green arrow: fitted direction of travel, faded when the plane fit is below its surrogate threshold. Dashed lines: fitted crests. Top view, nose up.

The same moment on the cortex

The clip above, painted on the fsaverage cortex of §04: the fourteen sensor values are spread over the surface with a smooth kernel centered on each site, and the color fades where no sensor is near. It follows the player's clock, so pausing, scrubbing or changing clip there changes this view too. Drag to turn.

What a clip can and cannot show

Each clip is a packet: a run of samples in which a plane fits the phase map better than 95% of channel-shuffled surrogates and the direction holds steady for several cycles. Packets are not rare. Across 36 ordinary recordings alpha produces 150 of them per clean minute — and spatially smooth noise with the same channel-to-channel correlations and no time lags at all produces 161, lasting just as long. A packet on fourteen sensors is therefore not, by itself, evidence that anything traveled. What lag-free noise cannot produce is a preferred direction: its packets point every way equally (index within ±0.03). Everything below rests on direction statistics, not on packet counts.

The clips were chosen by rule, not by eye: four or more cycles, low motion, high amplitude, and a phase that climbs as a ramp across the head rather than jumping as a step in at least half the samples. The front and back of the head in antiphase fits a plane almost as well as a real crossing does, and two lagged standing sources can mimic travel completely63; nowhere in the archive is there a long, smooth sweep. Speeds are nominal: on this montage the fitted spatial frequency is pinned near 2.3 rad per head radius whatever the truth. Unlike the arrows of §12, whose sign convention is unvalidated, the direction here is the direction of travel, checked against simulated waves of known direction under the average reference.

Where the direction survives: eyes closed, under LSD

Count the packets of two or more cycles that head toward the nose, subtract those heading toward the back, divide by their sum. Ordinary recordings lean back-to-front whenever the eyes are open: +0.19 pooled over 2,200 clean minutes, positive in 21 of the 22 recordings with at least three eyes-open minutes analyzed in September and in every one of the twelve ordinary recordings added in October (+0.09 to +0.37), anywhere from −0.05 to +0.49 depending on the day. Close the eyes and the lean disappears: +0.01 ± 0.01 pooled over 132 clean minutes, a median of +0.01 over the recordings with at least three closed minutes (the eyes-closed minutes of the October workdays fell almost entirely inside the photic sweeps, which are masked, so each of those recordings contributes about two minutes). That is what the literature on alpha waves describes — forward waves with visual input, none or backward at rest61,62.

Every eye-state split in this section carries one caution. Outside the timed blocks, eye state is the estimate of the classifier described in §16, and that classifier reads posterior alpha power, the height of the alpha peak and the posterior-to-frontal alpha ratio. Sorting windows by its label therefore also sorts them partly by alpha strength, and packet direction is measured from alpha. Sessions under protocol P2 and later open with timed eyes-open and eyes-closed blocks, labeled by the clock rather than by alpha, and those blocks are the cleaner test.

Left: the back-to-front index of every recording with at least three clean minutes in that eye state (whiskers ± 2 standard errors; gray band, the range of the lag-free null; bar, the median). Right: LSD experiment 016 in four stretches, the dose taken at minute 20. Hover for the recording. Data (CSV)

The six LSD sessions look like ordinary recordings while the eyes are open (+0.18 to +0.36). They differ with the eyes closed, where the lean stays: +0.25 to +0.35 in six of six. LSD experiment 016 shows it arriving. Before the dose, eyes-closed alpha had no direction (+0.02 ± 0.07, the same as every ordinary recording); by minutes 48–65 it was +0.41, and eyes-open alpha rose alongside it, +0.05 to +0.38. Eyes-closed packets also run far longer under LSD — the longest 1% last 22 to 100 cycles against 16 in ordinary eyes-closed alpha, where the null gives 14.

This is the archive's first state difference that holds with eye state matched, and it has a precedent: with eyes closed, DMT strengthens forward alpha waves and weakens backward ones, reproducing the pattern of eyes-open visual stimulation60. The result here is consistent with, but not sufficient to establish, the same reading for LSD — visual cortex behaving behind closed eyelids as though it were being shown something. The limits are plain. Six sessions, one person. Much of the ordinary eyes-closed time was recorded during photic stimulation, though the two flicker-free cases agree (−0.02 ± 0.04 and −0.11 ± 0.04). The index is a lag asymmetry, not a measured wave. And the DMT, ayahuasca and psilocybin sessions have not yet been split by eye state.

Psilocybin and ayahuasca show the same thing. The three psychedelic sessions recorded after this section was written were run through the same packet chain. With the eyes closed the anterior-going excess is +0.34 ± 0.02 after the psilocybin dose (2,776 packets) against −0.02 ± 0.08 before it in the same session and the same posture (172 packets, about three minutes), and +0.27 ± 0.02 and +0.31 ± 0.03 in the two ayahuasca sessions; the longest 1% of eyes-closed packets reach 88, 50 and 75 cycles against 14 before the psilocybin dose. The within-session pre-dose contrast of the psilocybin session is the cleanest form of this comparison the archive has, because the eyes-closed baseline comes from the same evening; its pre-dose sample is small. Packet rates stay at or below the lag-free null in all three, as under LSD. Three compounds now show the eyes-closed forward lean; none of the twelve ordinary recordings added in October does (ten of eleven at or below +0.04 with the eyes closed).

Ordinary recordings have the same waves

The second group of clips comes from a search of all 24 ordinary recordings under the same rule. Their packets are as frequent, as long in the typical case (median 2.2 cycles) and as well fitted (ρ 0.87) as the LSD ones, and the best single examples — 4.6 cycles at ρ 0.96 in Workday recording 010, 7.9 cycles at ρ 0.94 in Resting baseline 002 — match or beat the LSD exemplars. They run sideways and obliquely as often as front to back; on a montage with eight frontal and four posterior contacts that is partly geometry. No clip separates one state from another. The direction statistics do that.

Beyond alpha: one slow mode, and it is probably the eyes

Twenty-one narrow bands from 2 to 38 Hz, each run through the same packet pipeline beside its own lag-free null, in all 16 acute sessions and the eight longest ordinary recordings (first 60 clean minutes of each). Lines: median across recordings; shading: interquartile range; dashes: the null. Data (CSV)

A direction of travel exists in one place: 9 to 12 Hz, back to front, in 14 of 16 acute sessions and all eight ordinary ones, with a direction consistency of 0.05–0.10 against a null of 0.007. Theta, beta, the alpha harmonic and gamma make packets as often and as long as their nulls and point nowhere (consistency under 0.05 throughout). Rotating patterns occur in 57–64% of samples in every band — and in the null. Only acute sessions have packets longer than lag-free noise allows, and only at 10–11 Hz (the longest 1% reach 20–22 cycles against 17; nine of 16 sessions exceed their null by a quarter, none of the ordinary eight).

The scan was repeated on the fifteen October recordings. In the alpha band the anterior-going index of the first 60 clean minutes is 0.08 to 0.31 for the twelve ordinary recordings (null −0.03 to +0.03) and 0.25, 0.25 and 0.30 for the two ayahuasca sessions and the psilocybin session; the 99th-percentile packet length is 7 to 10 cycles in the ordinary recordings (null 7 to 12) and 13, 21 and 48 cycles in the three psychedelic sessions (null 12, 15 and 17). Theta, beta and gamma again point nowhere.

Two modes stand outside alpha. At 2–3 Hz packets run front to back: index −0.30 in the acute sessions (13 of 16 negative, the DMT sessions lowest at −0.42 to −0.53), −0.09 in ordinary recordings. The frontal contacts of this headset sit above the eyes, so a slow frontal-first pattern is what eye movements look like; it is reported as a mode and read as ocular until shown otherwise. And on the plateau of LSD experiment 016 the 5–6 Hz band acquires a steady left-to-right direction (consistency 0.14–0.19 against 0.01; at the null level before the dose) — in exactly the minutes when §11 finds that line coherent with head motion. Beta and the harmonic do lean weakly toward alpha's direction of the moment (28.6% of samples within 45° against 25.9% by chance; 14 of 16 acute sessions, all eight ordinary), and keep doing so when alpha's waveform shape is removed. No band's direction predicts another's at any lag.

Two waves at once

Any alpha field on fourteen sensors can be written as a sum of plane waves, so finding two is not the question; whether they behave as two is. At every sample the field was fitted with the strongest plane wave, then the strongest second one at least 45° away, then both amplitudes jointly. A pair is a run of three or more cycles in which both directions hold, the second wave is at least half the size of the first, and adding it explains more than it does in 95% of lag-free noise. The first two clips under "Two waves at once" in the player show such pairs, each as the total field beside its two component waves.

Stable pairs are rare — 0.2 to 1.3 a minute in the six LSD sessions, 0.1 to 0.2 in ordinary recordings — and in the four longest LSD sessions four in five are head-on. The commonest is not front-against-back, which lag-free noise produces just as often, but left against right: 44 such pairs in LSD experiment 016 against 9 in its null, 84 against 3 in LSD experiment 008, more than the null in five of the six LSD sessions. Within a pair the two waves share a frequency (0.1–0.2 Hz apart) and wax and wane together (r = +0.70 to +0.92), but less tightly than in the null (+0.84 to +0.99) in every recording. In about 30% of pairs — 28 to 32% in all six LSD sessions — the lead changes hands before the pair breaks up. Afterwards the wave that began stronger carries on alone in 38–40% of cases in the four longest sessions, the weaker one in 21–28%, and something else takes over in the rest. Neither wave's amplitude leads the other's at any lag up to half a second.

Four plane waves — forward, backward, rightward, leftward — fitted jointly at every clean sample. Phase locking is the resultant length of the relative phase while both waves are above their median size. Open circles: the same recording as lag-free noise. LSD experiment 016 is also shown split at the dose. Data (CSV)

Fitting all four axis-aligned waves at once shows how they relate over whole recordings. Forward and backward are strongly phase-locked (0.72–0.95 in the LSD sessions), which is what a standing pattern is — but in all nine recordings they are less locked than the lag-free null (0.90–0.98), where the front–back pattern is perfectly rigid. The real pair slips: two waves, tied but not welded. Across axes the result runs the other way. A front–back wave and a sideways wave have no reason to keep a fixed phase, and in ordinary recordings they do not (0.18–0.30, the null's 0.19–0.26). In the four LSD sessions with the most clean data they do: 0.46 to 0.73 against 0.14 to 0.31, at the same relative phases from session to session (a backward wave within 25° of a sideways one; a forward wave roughly half a cycle from it), with their frequencies pulled together in three of the four (0.26–0.35 Hz apart against 0.33–0.46). In LSD experiment 016 the locking was absent before the dose (0.17, below its null of 0.32) and present after it (0.53 against 0.31). The two shortest LSD sessions, with 26 and 44 clean minutes, do not show it.

That is an interaction in the plain sense: two waves holding a phase relation that instantaneous correlation cannot produce, appearing with the dose. What it is physically cannot be settled here. Two waves that entrain each other would give it; so would a single wave whose front is bent — alpha spreading outward from an occipital source runs forward along the midline and sideways at the flanks, and on fourteen sensors that is a forward wave locked to two sideways ones. Either reading makes the alpha field under LSD more than a standing pattern plus noise.

Waves in different bands

Two waves at different frequencies cannot hold a fixed phase, so they have other ways to interact. A nonlinearity can mix them, putting new lines at the sum and difference of their frequencies. The slow one can nest the fast one, gating its size with its phase — and if the slow wave travels, the fast wave's bursts should travel with it. They can lock n:m, one slow cycle to two fast ones. Or the slow wave can steer the fast one, biasing which way it runs. All four were tested across delta, theta, alpha, beta and gamma in the same nine recordings.

Bicoherence over every pair of frequencies from 2 to 24 Hz (posterior sites, 2-second windows): how consistently the phases at f₁ and f₂ predict the phase at f₁ + f₂. A bright cell means the two frequencies mix. Left, an LSD session; right, a workday. Cells below the 99.9th percentile of phase-randomized surrogates are blank. All cross-band tests (CSV)

Mixing: none outside alpha's own family. The map has one bright region, alpha with itself (0.42–0.65 in the LSD sessions and eyes-closed rest), and a fainter one where alpha meets its harmonic (0.08–0.22) — the waveform of §11. Nothing sits where a slow wave would mix with alpha: the strip of slow-frequency × alpha cells peaks only at its edge, against alpha's own skirt. The one other feature, delta with delta (0.14–0.26), is in most recordings and strongest over the forehead with eyes open, which is the shape of a blink.

Nesting: the slow waves do not gate alpha. Delta and theta phase leave alpha's amplitude alone (theta: z below 1 in all nine recordings; delta: never above 2.2). They do gate beta, weakly (modulation 0.01–0.02; z up to 22), in eight of nine recordings and most of all at the desk with eyes open — again where eye movements are, since a sharp transient is a slow deflection with fast edges. Alpha gates beta in five of the six LSD sessions, and there the beta bursts travel with the alpha wave: same direction to within 13° in LSD experiments 008, 011, 015 and 016 (z 3.4 to 7.1), not in ordinary recordings. Since "beta" under LSD is largely alpha's harmonic, this is the waveform traveling with its wave rather than a second oscillation riding it. No other envelope travels with its carrier.

Steering and locking. The phase of delta or theta does not bias alpha's direction (the forward-minus-backward balance swings by under 0.005 across a slow cycle; z −1.7 to 2.9). Alpha locks 2:1 to the band at half its frequency only faintly (0.02–0.06), clearing its null in LSD experiments 015, 011 and 016 — and in LSD experiment 015 without any accelerometer coherence at that frequency (0.02, against 0.26 in experiment 016), so the faint half-frequency partner of §11 is not always a head movement.

Across bands, then, the waves largely ignore one another. What looks like cross-band interaction is one non-sinusoidal alpha wave occupying several bands at once, and the eyes occupying the rest.

Four further tests, one oscillation

Tests of whether the harmonic, the two directions along the front–back axis, or distant sites behave as separate interacting waves; none does. Six LSD sessions and four ordinary recordings. Open circles are the null for that recording (circular time shifts, or lag-free noise), filled circles the measurement. Right: the phase of the harmonic relative to alpha at each site — near 0° over the front of the head, near 180° over the back. Data (CSV)

Alpha and its harmonic. A second wave at twice the frequency would have its own direction. The harmonic's fitted direction agrees with alpha's slightly more often than chance in every LSD session (28–34% within 45°, z 4 to 9.5), and it is phase-locked 2:1 to alpha at all fourteen sites. The locking phase is not uniform across the head: it sits near 0° over the front and near 160° over the back. That is what the average reference does to a front–back alpha pattern whose waveform is not a sine — flip the polarity and the harmonic's phase shifts by half a cycle while twice the alpha phase does not. One waveform, seen from both sides.

Coupling across the head. The bicoherence that ties α to 2α (§11) is as strong between sites as within one: 0.37–0.54 for a frontal pair feeding a posterior harmonic against 0.21–0.38 at a single site in the LSD sessions, the same in eyes-closed ordinary recordings, absent with eyes open. If every site carries the same alpha, every triplet of sites carries the same nonlinearity; this is not distant regions interacting.

Forward against backward. If opposite-going waves competed, one would fall as the other rose. They rise and fall together (r = +0.84 to +0.88 in the LSD sessions; +0.41 to +0.65 in lag-free noise), and once total alpha amplitude is removed the remaining anticorrelation (−0.05 to −0.23) is weaker than the null's (−0.34 to −0.48). At "collisions" — both components strong and balanced — the amplitude minimum sits at F3/F4 or T7/T8, exactly where it sits at random moments of matched amplitude: the montage, not a node.

The October sessions, through the same tests. Two of the LSD signatures reappear in all three new psychedelic sessions: when an alpha packet and its harmonic coincide, the alpha packet is forward-going 0.53 to 0.71 of the time under ayahuasca and psilocybin (0.24 to 0.31 in the twelve ordinary October recordings; 0.40 to 0.67 under LSD and 0.20 to 0.36 in the ordinary recordings of September), and in the forward-against-backward competition the backward fraction is 0.04 to 0.09 (ordinary 0.13 to 0.15). Posterior alpha-with-alpha bicoherence is 0.36 to 0.44 in the three sessions and 0.21 to 0.43 in the ordinary recordings whose alpha sits at 10 Hz (0.06 to 0.11 in the two 9 Hz recordings), and the alpha-with-harmonic term 0.09 to 0.12 against 0.03 to 0.13: the mixing picture of §11 holds, with no new cell lit outside alpha's own family.

The 10.9 : 5.4 : 2.7 Hz chain. On the plateau of LSD experiment 016 the (5.4, 5.4 → 10.9) bicoherence is significant at eight of fourteen sites — and in the accelerometer's own signal (z 3.6). The chain is the head movement of §11, locked to alpha.

Two waves can always be found. Under LSD they hold a phase relation that a standing pattern cannot — sideways locked to front–back — and the forward lean survives closed eyes.

14 — Hemispheric asymmetry Retrospective · exploratory

A right-leaning brain — and how much of it is the headset

Analysis basis 56-recording cohort (19 vs 37 for the state contrast) · dataset release 2026.10.10 · last recomputed in analysis release 4.26 · current

Right-hemisphere periodic power exceeds left in most bands and most recordings. All asymmetry here is computed on periodic power: each channel's own 1/f background is fitted and subtracted first, so a difference in background offset between hemispheres cannot masquerade as an oscillatory difference.

The claim, in five lines

Observation
After 1/f correction alpha, beta and theta power lean right in most recordings, and the lean is weaker in psychedelic-labeled sessions.
Status
56 recordings; 19 vs 37 for the state contrast; not state-matched. Retrospective.
Interpretation
A genuine hemispheric asymmetry that relaxes in altered states.
Alternatives
Contact quality at P7 and T7 (flagged in 30–35% of windows), gain imbalance, and state-dependent artifact composition. Equal left and right frequency does not bear on this: gain does not move frequency.
Discriminating test
Matched impedances and a left–right flip of the headset, once with eyes open and once closed.
BandRight − leftRecordings right-dominantReading
Alpha+46%76%Robust lateralization
Beta+74%88%Strongest of all bands
Theta+41%69%Present, weaker
Gamma+13%64%Marginal; muscle-sensitive
Delta−17%41%None

The lateralization is an alpha–beta–theta phenomenon. Delta shows none at all, which is itself informative: a pure electrode-gain imbalance would lateralize every band equally, and it does not.

Band
Signed periodic-power asymmetry per recording; positive means right greater. Hover for values, click to open a recording. Data (CSV)

It lives at the back of the head

Alpha asymmetry by homologous region. Posterior pairs are strongly right-dominant; frontal pairs sit near zero. Red marks the two regions containing a chronically unreliable electrode.

Frontal-polar lands at -4% and is right-dominant in only 43% of recordings. Parietal is right-dominant in 56 of 56 and occipital in 86%.

What the correction cannot fix

Subtracting the background removes differences in the shape of the 1/f curve, not a uniform gain difference. An electrode making poor contact attenuates the oscillation and the background together. The two largest regions, temporal (+116%) and parietal (+103%), are precisely the pairs containing P7 and T7, which carry degraded signal-quality flags in 35% and 30% of all windows — so the magnitude at those pairs is not trustworthy.

One fact argues against a purely fixed-gain story: the asymmetry changes with state, and a constant electrode imbalance alone would produce the same offset in every condition. (That both hemispheres run at the same frequency — right-over-left alpha center-frequency ratio 1.000, range 0.90–1.02 — is not evidence either way: a gain error scales amplitude and leaves frequency untouched, so equal frequencies are exactly what the artifact predicts.) The state dependence is itself qualified, because contact quality, signal-to-noise ratio and artifact composition also change with state and session.

The state effect, which is the part worth believing

Alpha asymmetry, non-psychedelic
+69%

Median across all non-psychedelic pair-recordings.

Alpha asymmetry, psychedelic
+10%

The lateralization nearly disappears under a psychedelic.

Side switches
5× more

19.2 per hour under psychedelics against 6.6 across the 28 workday recordings (3.9 in the fifteen original office recordings).

Treat absolute right-over-left numbers as provisional until the headset is tested with matched impedances and a left–right flip of the cap. The state dependence argues against a simple fixed-gain explanation, but an instrumental contribution to the difference between states remains unresolved until that test is run.

State, not only instrument, may set the sign

The September recordings enter the 1/f-corrected asymmetry above. No cap flip or impedance test was done, so the instrument limit stands. One new observation bears on it: the two eyes-closed photic sessions lean left on the whole-recording signed alpha measure while the three eyes-open or LSD-labeled sessions lean right, so state as well as instrument may set the sign; a flip test with eyes closed is the version to run.

15 — The office state Retrospective · exploratory

An office state with restricted dynamics

Analysis basis 28 workday recordings (27 of at least twenty minutes) against 4 resting and 19 psychedelic recordings; 12 for the September time-on-task analysis; 55 for the performance-score correlations · dataset release 2026.10.10 · last recomputed in analysis release 4.26 · current

The most personally useful result in the archive came from the least exotic recordings. Twenty-eight recordings of ordinary office work describe a state that is quieter and — most strikingly — dynamically frozen; the slowing reported in September did not survive the thirteen office recordings added since. (Every workday recording is pooled here, with its rest blocks and light stimulation masked; the fifteen original office recordings are the basis of the time-on-task and switching-by-task analyses below.)

Office work versus non-psychedelic rest across six measures, plotted as rest ÷ work. Alpha frequency barely differs. Everything about the dynamics differs enormously.

The comparison after reclassification

The ratios above were computed against the original four-recording rest group, three of which are now known to be DMT sessions. Recomputed against the corrected 15-session psychedelic group, and restricted to office recordings of at least twenty minutes so a three-minute clip cannot manufacture a zero: office alpha state switching is 5.0 per hour against 45.7 (p < 0.001; 27 office recordings of at least twenty minutes against 19 psychedelic sessions), and office alpha frequency is 9.96 Hz against 10.26 Hz (p < 0.001). The frozen-office finding is not an artifact of the mislabeled group; the office slowing, which was 9.21 Hz in the fifteen original recordings, is a difference of 0.3 Hz against the psychedelic sessions and none against the resting recordings on the 56.

Alpha frequency
+0.03 Hz

9.95 Hz at work against 9.92 Hz in the four resting recordings and 10.26 Hz under psychedelics. The slowing of September (9.82 against 10.11 Hz) is withdrawn: with the office recordings of September and October included, the workday peak sits at the ordinary median.

Alpha share
2.5× lower

Alpha's share of the spectrum is 0.18 at work against 0.45 at rest. Expected and healthy: eyes-open screen work is supposed to suppress alpha.

State switches
4× fewer

5.3 per hour across the 28 work recordings against 21.1 in the 4 resting ones and 45.7 under psychedelics. In two sessions the alpha field never reorganized at all.

State entropy
4× lower

0.263 against 1.072. The repertoire collapses to a single configuration.

The headline is not the low alpha. It is that the field's spatial configuration rarely changed — an association with the office context, not yet a mechanism.

Low alpha at a screen is normal reactivity. A spatial field that holds one configuration for an entire hour is a different thing — a narrow, low-vigilance regime rather than an actively cycling one. It also degrades across a session (the September analysis of the twelve original office recordings long enough for it): posterior alpha falls with time-on-task in 9 of the 12, and the slow/alpha ratio rises in 10 of 12, losing roughly 13% of alpha between the first and last quarter.

Do not trust the headset's own scores

The device reports Focus and Engagement as higher during office work than at rest. Across the 55 cohort recordings that carry the device performance scores, Engagement correlates ρ = -0.56 (p < 0.001) with alpha center frequency and +0.52 with the slow/alpha ratio; against alpha power the correlation is -0.77. These are inverse-alpha detectors: anything that suppresses alpha — genuine engagement, a bright screen, or a dull afternoon — pushes them up. They cannot distinguish concentration from torpor.

And it is not an electrode problem

Contact quality is 4/4 across essentially every office recording, so the low amplitude is real signal. But the device's separate signal-quality flag singles out one channel: P7 is degraded in 34.9% of all windows, the worst on the headset, against 10.8% for P8, the best. Any analysis leaning on P7 deserves suspicion; P8 can be trusted.

Two later desk recordings, split by task

Two later office recordings split by task rather than room. A 77-minute stretch of eyes-open desk work reproduces the frozen state above — 1.6 alpha-state switches per hour, wave-state entropy 0.06, alpha peak 9.16 Hz, alpha share 0.33 — and reproduces the time-on-task decline (posterior alpha ρ = −0.56 across 36 windows). A 17-minute recording in the same office that opened with the eyes-closed block and then a flicker sweep does not: 37 switches per hour, entropy 1.43, peak 9.99 Hz, share 0.90. Within the resting session the posterior peak moved from 8.92 to 10.23 Hz on eye closure alone, larger than the office-versus-rest frequency gap. The restricted regime follows eyes-open screen work, not the building. The device's Engagement score was highest in the low-alpha desk session and lowest under LSD, as the inverse-alpha reading predicts. §18.

← Program B · Nonlinear dynamicsEvidence ledgerProgram D · Altered-state comparisons →
theoscillome

A single-subject EEG archive: 56 recordings, 100.1 hours, 19 acute sessions, four psychedelic classes, 34 photic resonance sweeps, thirteen light-noise runs, one brain, February to October 2026. All 56 recordings form the analysis cohort.

theoscillome.com
February–October 2026
Non-diagnostic research